Marine pump
-
Marine Fire Pump
-
Marine Emergency Fire Pump
-
Marine Ballast Water Pump
-
Marine Fuel Pump
-
Marine Lubricating Oil Pump
-
Marine Bilge Pump
-
Marine Sewage Pump
-
Marine Domestic Water Pump
-
Marine General Pump
-
Marine Cargo Oil Pump
-
Marine Hand Pump
-
Marine Pump Parts
-
Marine Automatic Control Pump
-
Marine Centrifugal Pump
-
Marine Screw Pump
-
Marine Gear Pump
-
Marine Vortex Pump
-
Marine Ejector Pump
-
Marine Diaphragm Pump
-
Marine Piston Pump
-
Marine Self-priming Pump
Chemical pump
Urban pump
Other pump
Civil Pump
Submersible Pump
Contact us
Fushi Pump Chongqing Co., Ltd
Address: No. 11, Tianxing Avenue, ShuangQiao Industrial Park, Chongqing,China
E-mail: sales@fspumps.com
Tel: +86-23-67956606
Fax: +86-23-67956622
Mobil: +86-18983389474
CIS Marine Horizontal Centrifugal Cargo Oil Pump
Date:2022-07-01Views:
CIS Marine Horizontal Centrifugal Cargo Oil Pump
Description:
CIS type is kind of marine horizontal centrifugal fire pump applied in industrial, urban, fire water supply and drainage, and can also be used for irrigation and drainage of farmland and orchards and so on. It adopts conveying water with temperature less than 100℃ and maximum working pressure not more than 1.6MPa or liquid with similar physical and chemical properties to clear liquid. In addition, CIS series fire pump has another model CISR which adpots hot water whose liquid temperature does not exceed 200℃, which has good performance parameters, convenient installation size and model, and is also suitable for marine boilers and hot water supply.
Features
1. Compact structure, this series of pumps is a horizontal structure, the pump is integrated, the appearance is beautiful, and the floor area is small. Compared with the ordinary horizontal pump, the floor area is reduced by 30%. If the IP54 outdoor motor is used, there is no need for a pump room, and it can be used outdoors.
2. Smooth operation, low noise and high concentricity of components. The motor and the pump are directly connected, which simplifies the intermediate structure and increases the stability of operation. The impeller has excellent dynamic and static balance, no vibration and low noise during operation, which prolongs the service life of the bearing and improves the operating environment.
3. The shaft seal adopts high-quality mechanical seal, and the dynamic and static rings are made of hard alloy, which is wear-resistant, leak-free and has a long service life.
4. Adopt advanced hydraulic model, which has the characteristics of high efficiency and good performance.
5. The structure is unique. There is a drain hole on the lower side of the pump body. The inlet and outlet methods are constructed by pressure holes, which can ensure the normal operation of the pump.
Working conditions
1. The maximum working pressure of the pump system is 1.6MPa, that is, the suction port pressure of the pump + the pump head ≤ 1.6MPa (when the working pressure of the pump system is higher than 1.6MPa, it should be separately proposed when ordering, so that the overflow parts and The connecting parts are made of cast steel).
2. The conveying medium is clear water or other liquids with physical and chemical properties similar to clear water (if the conveying medium has fine particles, it should be separately proposed when ordering, so that the wear-resistant mechanical seal can be assembled).
3. The ambient temperature should not exceed 40℃, the altitude should not exceed 1000m, and the relative humidity should not exceed 95%.
Model Explanation:
CIS Marine Horizontal Centrifugal Cargo Oil Pump | Detail-CIS (R),CIH80-65 -160A(B, C) |
CIS—Marine centrifugal pump | |
R—Hot water | |
80—Inlet diameter 80mm | |
65—Outlet diameter 65mm | |
160—Impeller diameter 160mm | |
160—Impeller diameter 160mm |
Parameter of CIS Marine Horizontal Centrifugal Cargo Oil Pump:
(In addition, please provide the parameter of the marine pump you need and we can customize the suitable type for you.)
Main technical parameter
Precautions for use
1. The maximum working pressure of the pump and the connected pipeline is ≤1.6MPa, and the pressure at the suction port of the pump + the pump head is ≤1.6Mpa. (If the working pressure of the pump system is greater than 1.6MPa, it should be put forward separately when ordering, so that we can use cast steel for the over-current parts and connecting parts of the pump during manufacture).
2. The ambient temperature does not exceed 50°C, the altitude does not exceed 1000 meters, and the relative humidity does not exceed 95%.
3. The conveying medium is clear water or other liquids with similar physical and chemical properties to clear water. (The conveying medium contains fine particles, which should be specified separately when ordering, so that we can assemble the wear-resistant mechanical seal.)
4. Before installing the pump, carefully check whether there are hard objects (such as stones, iron particles, etc.) in the pump flow channel that affect the operation of the pump, so as to avoid damage to the impeller and pump body when the pump is running.
5. The weight of the pipeline should not be added to the pump during installation, and there should be their own support bodies to avoid the deformation of the pump and affect the running performance and life.
6. The anchor bolts must be tightened during installation to avoid the impact of vibration on the pump performance during startup.
7. For the convenience of maintenance and safe use, a regulating valve is installed on the inlet and outlet pipelines of the pump and a pressure gauge is installed near the pump outlet to ensure the operation within the rated head and flow range, to ensure the normal operation of the pump and the growth of the pump. service life of the pump.
8. After installation, turn the pump shaft, the impeller should have no friction noise or stuck phenomenon, otherwise the pump should be disassembled to check the cause.
Maintenance
(1) Maintenance and maintenance during operation:
1. The water inlet pipeline must be highly sealed.
2. Long-term operation of the pump under cavitation is prohibited.
3. It is forbidden to run the motor over-current for a long time when the pump is running at a large flow rate.
4. Regularly check the current value of the motor during the operation of the pump, and try to make the pump work under the standard.
5. During the operation of the pump, there should be a special person to take care of it to avoid accidents.
6. The bearing should be refueled every 500 hours of operation of the pump. Motor power greater than 11 kW is equipped with a refueling device, which can be directly injected with a high-pressure oil gun to ensure excellent bearing lubrication.
7. After the pump runs for a long time, when the noise and vibration of the unit increase due to mechanical wear, it should be stopped for inspection, and the vulnerable parts and bearings can be replaced if necessary. The unit overhaul period is generally one year.
(2) Mechanical seal maintenance and maintenance:
1. The lubrication of the mechanical seal should be clean and free of solid particles.
2. It is strictly forbidden to work under the condition of static dry grinding of mechanical seals.
3. Before starting, the pump (motor) ring should be rotated, so as to avoid the sealing ring being broken and damaged due to sudden start.
Troubleshooting
Failure | Possible causes | Solutions |
1.No water out of pump | a.Inlet and outlet valves not opened, inlet and outlet pipes jammed, or flow passage impeller jammed. b.Improper running direction of motor or low seed of motor due to open phase. c.Air leakage of suction pipe. d.Pump not filled up with liquid, or air existing inside pump. e.Insufficient inlet water supply, overhigh suction head, or water leakage at bottom valve. f.Excessive resistance of pipeline, or improper use of pump model. | a.Check and clear the jamming b.Adjust the running direction of motor, or fasten motor connections. c.Fasten the seal faces, and clear away the air. d.Open the upper cover of pump or open exhaust valve to let air completely out. e.Stop for check and adjustment (often happened to water supply pipe network and service with suction head) f.Reduce the bends of pipeline, or reselect a pump |
2.Insufficient flow of pump | a.1.Check the causes according to 1. b.Pipeline or impeller in flow passage partially jammed, scale deposited of valve. c.Voltage being low. d. Impeller worn out. | a.1.Solutions according to 1. b.Clear away the jamming, or readjust the opening of valve. c.Stabilize the voltage. d.Replace the impeller. |
3.Excessive power. | a.Service beyond the rated flow. b.Over high suction head. c.Pump bearing worn out. | a.Adjust the flow and lessen the opening of outlet valve. b.Lower. c.Replace the bearing. |
4.Noise and vibration | a.Pipeline not steadily supported. b.Liquid mixed with air. c.Cavitations produced. d.Bearing damaged. e.Motor running overloaded and heated. | a.Fix the pipeline. b.Enhance suction pressure, and exhaust. c.Lower the degree of vacuum. d.Replace the bearing. e.5.Adjustment according to 5. |
5.Motor heated | a.Excessive flow, overloaded operation. b.Scratch. c.Motor bearing damaged. d.Under voltage. | a.Lessen the opening of outlet valve. b.Check for solutions. c.Replace the bearing. d.Stabilize the voltage. |
6.Water leakage of pump | a.Mechanical seal worn out. b.Sand holes or breakage on pump body c.Seal face irregularity. d.Mounting bolts loosened. | a.Replace. b.Weld or replace. c.Repair. d.Fasten. |
Picture of CIS Marine Horizontal Centrifugal Cargo Oil Pump
Photo of CIS Marine Horizontal Centrifugal Cargo Oil Pump:
Certificate: